Home / Products / Immersion Heaters / Flanged Immersion Heaters

Flanged Immersion Heaters

Industrial flange heatersFlanged immersion heaters are constructed by brazing or welding elements into an ANSI or plate flange. These are intended for direct immersion into fluids and gases. The heater is to be installed via a flanged port in the tank or vessel. Flanged immersion heaters are available in a variety of flange sizes and materials. The heating elements are offered in a number of materials suited to a variety of fluid heating applications. Terminal housings are available for indoor, outdoor (weatherproof NEMA 4) and hazardous (NEMA 7) environments. Many options are available including thermostats, high limit and process thermocouples or RTD sensors. Since we are a made to order company, we can offer a large selection of sizes and configurations which are not listed below. Please contact us for assistance with your application.

Standard Flange Sizes & Materials

ANSI Flange Size

ANSI Flange Rating

Materials

2″ – 24″

150 lb, 300 lb, 600 lb

Carbon Steel, Stainless Steel, Titanium

Common Sheath Materials

Copper

Steel

Stainless Steel

Incoloy 800 ®

Inconel 600 ®

Titanium

Potable Water

Fuel Oils, Hydraulic Oils

De-Ionized, R-O, Process Water, Mild Acids

Water, Mild Alkaline Solutions, Air and Gases

Water, Very Alkaline Solutions, High Temperature Air and Gases

Sea Water, Very Alkaline Solutions, Some Acid Solutions

Built in Thermostat Options

Power Ratings Up to 240 volts, 25-amp single pole, single throw (SPST)

Up to 240 volts, 25-amp double pole, single throw (DPST)

Up to 600 volts, 15-amp triple pole, single throw (TPST)


Temperature Ratings 0 – 100° F
50 – 250° F
160 – 540° F
320 – 700° F

Built In Sensor Options

Sensors “K” thermocouple for high limit sheath protection and fluid sensing and temperature control.

“J” thermocouple for high limit sheath protection and fluid sensing and temperature control.

100 Ohm RTD Sensor for fluid sensing and temperature control.

Terminal Housing Options

3”-150 # ANSI Flanged Heaters

flange_02

General Purpose Housings
NEMA 1

flange_03

Moisture Resistant Housing
NEMA 4

flange_12

Hazardous Location
NEMA 7

4”-150 # ANSI Flanged Heaters

flange_04

General Purpose Housings
NEMA 1

flange_05

Moisture Resistant Housing
NEMA 4

flange_13

Hazardous Location
NEMA 7

5”-150 # ANSI Flanged Heaters

flange_06

General Purpose Housings
NEMA 1

flange_07

Moisture Resistant Housing
NEMA 4

flange_14

Hazardous Location
NEMA 7

6”-150 # ANSI Flanged Heaters

flange_08

General Purpose Housings
NEMA 1

flange_09

Moisture Resistant Housing
NEMA 4

flange_15

Hazardous Location
NEMA 7

8”-150 # ANSI Flanged Heaters

flange_10

General Purpose Housings
NEMA 1

flange_11

Moisture Resistant Housing
NEMA 4

flange_16

Hazardous Location
NEMA 7

Non-Standard Flange Options / Designs

flange_20

Square Flange
Available in various sizes

flange_18

Round Flange
Available in various diameters

pipe_02

Pipe Insertion
Available in various diameters

Flange Heaters

EXTRA FEATURES DESCRIPTION 
VOLTAGE Flange heaters are custom-built and supplied with voltages up to 600V.
WATTAGE Custom made heaters can be supplied with any requested wattage.
LENGTH Flange heaters are supplied with unlimited immersed lengths. When the immersed length exceeds 50”, it is recommended to install an internal vessel support.
EXTRA HEAVY WALL SHEATH Heavy wall sheath (0.035” or 0.065” thickness) is provided in: • Incoloy® • Inconel® • Steel • Stainless steel
FLANGE SIZES AND RATINGS Refer to the Welding flanges section on page 2.12 and 2.13
PASSIVATION Available Incoloy® and stainless steel sheathed heaters are supplied with chemically passivated sheaths. Note: Chemically passivated sheaths are highly corrosion resistant in most applications. Passivation process is carried out through electropolishing. Stainless steel flange heaters can come with passivated wetted surfaces (Teflon on top of the sheath).
WELDED ELEMENTS Standard flange heaters are made of elements that are silver-brazed, ‘TIG’ or welded to the flange. Heaters are supplied with welded elements for the following sheath material: • Incoloy® • Stainless steel • Steel • Copper
BUILT-IN THERMOSTAT WELL Built-in thermostat wells can be installed upon request. When ordering, please provide length and internal diameter.
BUILT-IN HIGH LIMITS AND THERMOSTATS For process temperature control, built-in high limits and thermostats can be installed upon request. Standard built-in thermostats: Single pole device of a maximum of 600V up to 25 amps
BUILT-IN THERMOCOUPLES Thermocouples can be mounted to provide sheath limit protection or temperature control. Configured temperature control and power controls are available to meet the requirements of any application.
VENTED or STAND OFF Vented or Stand off housings prevent the connection wire from overheating in many high temperature applications.
SPECIAL TERMINAL HOUSINGS Special terminal housings for all types of flange heaters can be made: • Moisture resistant • Explosion resistant When requesting an explosion-proof housing, please provide: • Class • Division or zone • Group • Temperature code for unsafe locations (Refer to Figures 1-4)
Flanged Heater Applications SHEATH MATERIAL FLANGE MATERIAL
Clean water, Freeze protection, hot water storage, Boiler and water heaters, cooling towers Copper Steel
Hot water, steam boilers, mildly corrosive solutions (in rinse tanks, spray washers) Incoloy Steel
Oils, Gases, Mildly corrosive liquids, stagnant or heavy oils, high temperature, low flow gas heating Steel Steel
Process water, soap and detergent solutions, Soluble cutting oils, demineralized or deionized water Stainless Steel Stainless Steel
Mildly corrosive solutions Stainless Steel Stainless Steel
Severe corrosive solutions, demineralized water Incoloy Stainless Steel
Light Oil, Medium Oil Steel Steel
Food Equipment Incoloy Stainless Steel
Features• Benefits
• Standard flange heaters: ½" to 42 inch pipe
• Easy to install
• 0.260”, 0.315”, 0.375”, 0.430” or 0.475”, 0.625” diameter 
• Easy to control
• 150lb, 300lb, 600lbs or 900lbs forged steel flange
• Easy to maintain
• Steel, Incoloy®, inconel®, stainless steel, copper or titanium elements
• Perfect for higher kilowatt output applications
• Available explosion and/or moisture resistant terminal enclosures upon request 
(NEMA 1, NEMA 4, NEMA 4x or NEMA 7.

• Appropriate heater size provided for the application and fit 
• Available custom sizes, wattages, and materials upon request. 
• Designed and built for safety
• Heating units are custom-designed to meet your specifications. • CSA, CSA U.S. & UL approved
Top